Images/Measurements

Herpes Simplex Virus in buffer

Adsorbed onto silanized glass slide imaged in QI™ mode

Latest Product Info

QI™ mode - Quantitative Imaging

for imaging challenging samples with the NanoWizard® 3 AFM family

Atomic Force Microscopy

Accessories for the TAO™ module (tao accessories)

tao accessoriesAccessories for the TAO™ module

Accessories for the TAO™ module
filter:

Where performance meets flexibility

Optical systems/accessories, electrochemistry solutions, electrical sample characterization, environmental control options, software modules, temperature control, acoustic and vibration isolation solutions and more. - JPK provides you with the right accessories to control your sample conditions and to perform successful experiments.

Download accessories handbook

Vortis™ SPMControl station

  • State-of-the-art digital controller with lowest noise levels.
  • High speed 16bit AD conversion with 60 MHz for the photodetector signals
  • 24bit ultra precise ADC with 2.5 MHz

Signal Access Module - SAM

Upgrade for the Vortis™ controller for more flexibility.

NanoLithography/NanoManipulation module

Software module for NanoWizard® systems.

Conductive AFM (CAFM) module

For conductivity and I/V measurements on the nanoscale.

KPM and SCM module

Kelvin Probe (KPM) and Scanning Capacitance (SCM) Microscopy module. Option for nanoscale mapping of surface potential distribution.

STM module

The Scanning Tunnelling Microscopy (STM) module fits directly to the NanoWizard® head.

ForceWheel™

JPK‘s ForceWheel™ handheld accessory for most sensitive experiment control, e.g., for force spectroscopy.

Manual precision stage

Offers sub-micron resolution & fine motion control for precise positioning of the AFM tip relative to optical axis and the sample.

Cantilever holders

  • Standard holder for all-round applications with a large optical field of view
  • Supercut version for use in air or liquids with removable cantilever spring for maximum cleaning results.

CoverslipHolder

  • closed liquid cell with standard coverslip bottom
  • high-N.A. immersion optics possible
  • autoclavable

SmallCell™ small volume closed liquid cell

The perfect solution for smallest volume experiments in a hermetically sealed environment, two versions available for volumes <150µl and <60µl.

Heating Cooling Module - HCM™

Designed for heating and cooling experiments in gas or liquids with minimized drift in all dimensions.

HCS™ with electrochemistry cell

Designed for electrochemistry AFM experiments with controlled heating and cooling of the sample.

Vibration and acoustic isolation

from Accurion, Table Stable and TMC

JPK base for acoustic enclosure

Approved for high performance applications: base frame with top plate from JPK for utmost stability.

Cantilevers, substrates and standards

The JPK platforms are compatible with all commercially available cantilevers.

Vortis™ Advanced SPMControl station

  • State-of-the-art digital controller with lowest noise levels.
  • 4 high speed 16bit ADC channels with 60 MHz
  • 12 ADCs with 18bit with 800 kHz

Product note

DirectOverlay™ software module

Perfect integration of optical and AFM data – JPK‘s proprietary and patented solution for perfect overlay of optical and AFM information.
See also the product page for more information.

MicroRheology software module

For visco-elastic properties of living cells and other samples such as gels or foams.

Electrical sample connection module

Accommodates electrical conductive samples such as AFM metal stubs by magnetic fixation or transparent samples such as ITO coated glass coverslips.

CAFM module - enclosed volume

For experiments in inert atmosphere; for conductivity and I/V measurements on the nanoscale under controlled environmental conditions.

High Voltage Sample Bias Amplifier

Can be used for biasing a sample, e.g., in electro-optical experiments or in Piezo-Response Force Microscopy (PFM).

Motorized precision stage

Offers automatic motion control for precise positioning of the sample relative to optical axis and AFM probe.

Standard stage

Offers fine motion control for precise positioning of the AFM tip relative to the sample.

BioCell™ coverslip based liquid cell

Coverslip based fluid cell for Live Cell imaging and single molecule fluorescence with temperature control and perfusion

PetriDishHeater™

  • for Live Cell imaging
  • accomodates 35 mm Petri dishes even with glass bottom

High Temp. Heating Stage - HTHS™

  • polymer science
  • phase separation studies
  • temperature range from ambient to 300°C
  • resolution 0.1°C
  • drift compensated design

Heating Cooling Stage - HCS™

Designed for AFM experiments in air or liquids from 0°C up to 100°C with minimized drift in all dimensions – HCS™ follows the same design criteria as HTHS™.

ECCell™ electrochemistry cell

  • works with transparent or non-transparent substrates
  • temp. range from ambient to 60°C
  • 1200µL liquid volume
  • Product note

JPK acoustic enclosure

Approved for high performance applications: acoustic hood from JPK for utmost stability and isolation.

JPK sample holder for small samples

Adaptor for standard sample holder.
Holds magnetically fixed AFM metal stubs.